5. Tutorial 2 — Comparing Stack Heights¶
Goal: Create two versions of the same facility — one with a 20 m stack and one with a 60 m stack — to understand how stack height affects ground-level concentrations.
Time: 15--20 minutes
What you'll learn: - How stack height controls plume rise and ground-level impact - How to save and reopen project files to create scenario variants - How to read an AERMOD input file and spot key differences
Conceptual Background¶
Imagine two identical factories, both emitting 2 g/s of SO2. The only difference is the smokestack:
- Factory A: 20 m stack (about 6 stories tall)
- Factory B: 60 m stack (about 20 stories tall)
Which factory will cause higher ground-level concentrations? Intuitively, Factory A — its emissions are released closer to the ground, so they have less distance to dilute before reaching people.
But how much of a difference does it make? That's exactly what AERMOD calculates.
Step 1: Build the Base Scenario¶
Follow the same steps as Tutorial 1, but with these settings:
Project:
- Title (line 1): Tutorial 2 - Stack Height Comparison (20m)
- Pollutant: SO2
- Averaging periods: 1, 24, and ANNUAL
- Terrain: Flat (FLAT), with Regulatory default options (DFAULT) unticked
Source (PointSource):
- Source ID: STACK1
- Stack height (m): 20
- Stack temp (K): 420
- Exit velocity (m/s): 15
- Stack diameter (m): 2
- Emission rate (g/s): 2.0
Receptors (CartesianGrid):
- 4 km x 4 km area centered on the source, 100 m spacing
(X num and Y num 41, X delta and Y delta 100)
Meteorology:
- Surface file: met_data.sfc
- Profile file: met_data.pfl
Step 2: Save the Project¶
- Go back to the Project step.
- Click Save as..., enter the filename
tutorial2_20m.jsonand click Save. Your browser downloads the project as a JSON file.
Step 3: Download the 20 m Input File¶
- Go to Review & Run.
- Click Download deck. Rename the downloaded file
stack_20m.inp.
Step 4: Create the 60 m Variant¶
- Go to Sources.
- Click the Edit button on the
STACK1row of the table. - Change Stack height (m) to
60and click Save. Everything else stays the same. - On the Project step, update the title to
Tutorial 2 - Stack Height Comparison (60m). - Save this project as
tutorial2_60m.json(Save as...). - Download the input file and rename it
stack_60m.inp.
Step 5: Compare the Input Files¶
Open both .inp files in a text editor and find the SRCPARAM line of the
SO pathway:
20 m stack:
60 m stack:
The only difference is the second number (stack height); the title line differs too. Everything else is identical, making this a controlled experiment.
What to Expect When You Run These (Tutorial 3)¶
When you eventually run both files through AERMOD with real meteorological data:
- The 20 m stack will produce higher maximum ground-level concentrations, especially close to the source (within 500 m).
- The 60 m stack will produce lower maximum concentrations because the plume is released higher and has more room to dilute.
- The location of the maximum concentration will also shift — taller stacks push the peak concentration farther downwind because the plume takes longer to mix down to ground level.
In this exercise, stack height changes the ground-level concentrations from a point source the most.
Checkpoint¶
At this point you should understand:
- [x] Taller stacks reduce ground-level concentrations
- [x] Taller stacks push the peak concentration farther downwind
- [x] Saving the project under a new name (Save as...) lets you create scenario variants; Open... brings one back
- [x] The
SRCPARAMline of theSOpathway contains all point source parameters