Particle size distributions for Method 1 deposition¶
AERMOD's Method 1 particle deposition describes a source's particles as a
list of size categories. Three SO cards carry the list, one value per
category:
| Card | Meaning | What AERMOD checks (v26135 soset.f) |
|---|---|---|
PARTDIAM |
Diameter of the category, microns | Above 0.001 and at most 1000 (E335) |
MASSFRAX |
Fraction of the source's mass in the category | Each 0 to 1 (E332); a warning when they do not sum to 1 within 2% (W330) |
PARTDENS |
Particle density, g/cm³ | Above 0 (E334); a warning at or below 0.1 (W334) |
pyaermod.psd builds those lists from the way size data usually arrive,
cumulative mass fractions at a few cut points or a lognormal fit, and
returns the ParticleDepositionParams that a source's
particle_deposition field takes.
from pyaermod.psd import bins_from_cut_points
from pyaermod.sources import AreaSource
# AP-42 section 13.2.4 (aggregate handling): particle size multiplier k
# for the mass below 2.5, 5, 10, 15 and 30 microns (aerodynamic).
k = {2.5: 0.053, 5: 0.20, 10: 0.35, 15: 0.48, 30: 0.74}
edges = [0.5, 1, 1.6, 2.5, 3.5, 5, 7, 10, 12.5, 15, 20, 25, 30]
dist = bins_from_cut_points(k, edges)
dist.mass_fractions # 12 fractions that sum to 1
dist.fraction_at_or_above(10) # 0.527
source = AreaSource(
source_id="PILE", x_coord=0.0, y_coord=0.0, emission_rate=1.0e-5,
particle_deposition=dist.to_deposition_params(density=1.0),
)
What AERMOD does with the diameter¶
VDP1 in soset.f turns each category into a gravitational settling
velocity by Stokes' law with a Cunningham slip factor:
SCF = 1 + 2 xmfp (1.257 + 0.4 exp(-0.55 d / xmfp)) / d
Vg = max(0, rho - 1.2e-3) g d² SCF / (18 × 1.81e-4)
with d in cm, xmfp = 6.5e-6 cm, rho from PARTDENS in g/cm³ and
g = 9.80616 m/s². The diameter on PARTDIAM is therefore the
physical (Stokes) diameter of a particle of density PARTDENS.
psd.settling_velocity(d, rho) repeats the calculation;
tests/fixtures/psd/ holds a real AERMOD v26135 run whose
DEBUGOPT DEPOS output it matches, category by category, to the six
digits AERMOD prints.
Size data from emission factors and impactors are aerodynamic diameters: the diameter of a unit-density sphere that settles at the same speed. There are two ways to give them to AERMOD, and they settle the same:
- Aerodynamic diameters with
PARTDENS 1.0. This is whatto_deposition_params()does with its default density of 1. - Stokes diameters with the real density.
to_deposition_params(density=2.65)converts each diameter withaerodynamic_to_stokes, which solves AERMOD's own settling equation, so that(d_s, 2.65)settles exactly like(d_a, 1.0). Any density other than 1 converts;stokes=True, the older spelling, still does the same.
The ParticleDepositionParams that comes back records which kind it
holds in diameter_convention ("stokes" after a conversion,
"aerodynamic" at density 1), and the validator reads it: aerodynamic
diameters beside a density other than 1 draw a warning, because AERMOD
would settle every category about that many times too fast. A deck read
from a file has diameter_convention=None (unknown) and draws nothing.
A distribution measured as physical diameters (a sieve or laser
diffraction analysis) is passed as
to_deposition_params(density=2.65, diameter_convention="stokes"): its
diameters are written as they are, with no conversion.
The textbook conversion d_s = d_a / sqrt(rho) (slip=False) ignores
the slip factor. The smaller Stokes diameter slips more than the
aerodynamic one, so AERMOD settles it too fast. In the recorded run, at a
density of 2.65:
| Aerodynamic diameter (µm) | aerodynamic_to_stokes |
d_a / sqrt(rho) |
|---|---|---|
| 0.78 | same Vg as (0.78, 1.0) |
11% faster |
| 11.3 | same | 1.0% faster |
| 68.9 | same | 0.2% faster |
Two cautions:
- Only gravitational settling is matched. AERMOD's Brownian diffusion term depends on the physical diameter, so the two ways deposit fine particles at different rates, as real particles of those sizes would.
- Writing an aerodynamic diameter with a density above 1 models a
larger particle: the same diameter at 2.65 g/cm³ settles 2.65 times
faster in AERMOD (the recorded run's
AERO265source against itsAERO1). Earlier pyaermod releases wrote exactly that unlessstokes=Truewas passed.to_deposition_params(density=2.65, convert=False)still does, for a deck that must reproduce an existing one; it warns, and so does the validator.
Representative diameter of a bin¶
A bin from d1 to d2 goes to AERMOD as one diameter:
- Mean-mass (the default,
representative="mean_mass"):((d1³ + d1² d2 + d1 d2² + d2³) / 4)^(1/3), the cube root of the mean ofd³across the bin. From the edges 0, 1, 2.5, 5 and 10 microns it gives 0.63, 1.85, 3.88 and 7.77 microns, the diameters of EPA'ssurfcoaltest deck. - Settling-equivalent (
representative="settling_equivalent"):sqrt((d2² − d1²) / (2 ln(d2/d1))), the diameter whosed², and so whose Stokes settling velocity, is the mean over a bin whose mass is spread uniformly inln d. It needsd1 > 0.
from pyaermod.psd import SizeDistribution
surfcoal = SizeDistribution(edges=(0, 1, 2.5, 5, 10),
mass_fractions=(0.03, 0.07, 0.20, 0.70))
[round(d, 2) for d in surfcoal.diameters()] # [0.63, 1.85, 3.88, 7.77]
Building distributions¶
From cut points¶
bins_from_cut_points(cut_points, edges, lower=None, anchor=None,
tail=None) takes the cumulative mass below each cut point, in any
consistent units (AP-42's k values work as they are). Between cut
points the cumulative mass is linear in ln d. Below the first cut point
the mass is spread log-linearly down to lower (the first edge by
default), where it is 0; nothing is modelled below lower. Above the
largest cut point the cut points say nothing, so truncated_above is
None and bins that reach beyond it need tail= (see AP-42 stops at
30 microns).
From a lognormal¶
bins_from_lognormal(mmd, gsd, edges, anchor=None) bins a lognormal mass
distribution with mass median diameter mmd and geometric standard
deviation gsd, truncated to the edges. The mass left out of the bins
is reported as truncated_below and truncated_above, fractions of the
whole distribution, and the rest is renormalised to sum to 1. How an
emission rate treats the mass below the first edge is set by the anchor,
below.
From any cumulative distribution¶
bins_from_cdf(cdf, edges, anchor=None) accepts a LogLinearCDF, a
LognormalCDF or any object with the same interface: a call F(d)
that does not decrease with d, plus lower_limit and upper_limit
(its values towards 0 and infinity).
The emission rate and the anchor¶
MASSFRAX must sum to 1, but an emission factor refers to the mass below
a stated size, such as PM30. When the bins reach beyond that size (a
tail from 30 to 50 microns, say), or stop short of it, the modelled mass
differs from the emission factor's. anchor names the size the emission
rate refers to, and multiplying the anchor emission rate by
anchor_ratio gives the emission rate that goes with the fractions.
anchor_ratio is the mass in the bins divided by the mass between the
first edge and the anchor. With the anchor inside the edges, the
modelled mass below the anchor therefore equals the anchor's emission
rate. The two ends are treated differently:
- Below the first edge. Mass the distribution has there (a lognormal
truncated at 0.5 microns, or cut points with
lowerbelow the first edge) is not in the anchor's mass either, so the anchor's whole rate is spread over the bins: that fine mass is reassigned, not lost. This is what makes a distribution's modelled mass below 30 microns equal the AP-42 PM30 emission. - Above the last edge. When the bins stop short of the anchor, the
mass between the last edge and the anchor is part of the anchor's mass
but not of the bins, so it is lost and
anchor_ratiofalls below 1. AP-42 13.2.4's k-values on bins that stop at 15 microns giveanchor_ratio0.48/0.74 = 0.649 with the default anchor, 30 microns.
truncated_below and truncated_above report both, as fractions of the
whole distribution, whatever the anchor. truncated_above is None
when the distribution does not say what lies above the last edge: bins
that reach the largest cut point, or a power-law tail, which has no upper
limit (then truncated_below is None too, unless it is exactly 0).
# Cumulative mass relative to PM30, with 25% more mass between 30 and 50 um.
dist = bins_from_cut_points({2.5: 0.03, 10: 0.30, 30: 1.0, 50: 1.25},
edges=[0.5, 2.5, 10, 20, 30, 40, 50], anchor=30)
dist.anchor_ratio # 1.25
q_pm30 = 2.0e-5 # g/(s m²), from the emission factor
q_model = q_pm30 * dist.anchor_ratio
AP-42 stops at 30 microns¶
AP-42's particle size multipliers end at PM30: the 13.2.4 table says what
fraction of the emission lies below 30 µm and nothing about the mass
above it, which for a coarse source such as crushed or dropped material
may not be small. Cut points therefore cannot tell bins_from_cut_points
what to put in bins above the largest of them, and it does not guess:
- With edges that stop at the largest cut point, nothing is asked;
truncated_aboveisNone, because the mass above is unknown. - With edges beyond it,
tail=says what lies there. Left out, the bins above get no mass and aFutureWarningnames the choices; a future release will requiretail=there.
from pyaermod.psd import LognormalCDF, bins_from_cut_points
k = {2.5: 0.053, 5: 0.20, 10: 0.35, 15: 0.48, 30: 0.74}
edges = [0.5, 1, 1.6, 2.5, 3.5, 5, 7, 10, 12.5, 15, 20, 25, 30, 40, 50, 62.5, 75]
# No mass above 30 um: the bins above get 0, truncated_above is 0.
zero = bins_from_cut_points(k, edges, tail="zero")
# A power law: the cumulative mass continues as F(30) * (d / 30) ** m,
# the Gates-Gaudin-Schuhmann form for crushed material. With m = 1 the
# mass between 30 and 75 um is 1.5 times the mass below 30, so
# anchor_ratio is 2.5: the PM30 emission rate times 2.5 is the rate that
# goes with the bins. The power law has no upper limit, so
# truncated_above is None.
power = bins_from_cut_points(k, edges, tail=1.0)
power.anchor_ratio # 2.5
# A lognormal continuation: above 30 um the cumulative mass follows the
# lognormal's shape, scaled to agree with the cut points at 30 um,
# F(d) = F(30) * L(d) / L(30). Its upper limit is known, so
# truncated_above is the lognormal's mass above 75 um.
coarse = bins_from_cut_points(k, edges, tail=LognormalCDF(30.0, 2.5))
# Any object with the CumulativeMassDistribution interface works the
# same way, scaled to agree at the largest cut point.
Whichever tail is chosen, the mass it adds above 30 µm raises
anchor_ratio with the default anchor, so an emission factor stated for
PM30 is scaled up for the tail, and the fractions still sum to 1. The
choice is the modeller's: AP-42 gives no basis for it, and the deposited
mass near the source depends on it.
Method 1 or Method 2¶
AERMOD's User's Guide recommends Method 1 when a significant fraction of
the mass, more than about 10%, is in particles of 10 microns or more.
dist.fraction_at_or_above(10) gives that fraction, provided 10 microns
is a bin edge.
Options of to_deposition_params¶
| Argument | Default | Effect |
|---|---|---|
density |
1.0 | PARTDENS for every bin |
representative |
"mean_mass" |
Or "settling_equivalent" |
convert |
unset | Convert the aerodynamic diameters to Stokes diameters for density; unset converts whenever density is not 1. False writes them unchanged and warns when density is not 1 |
stokes |
unset | The older spelling of convert (True converts) |
slip |
True |
When converting, solve AERMOD's settling equation; False uses d_a / sqrt(rho) |
drop_empty |
False |
Leave out bins with no mass (AERMOD accepts a 0 fraction) |
diameter_convention |
"aerodynamic" |
"stokes" when the distribution's edges are already physical diameters of particles of density: written as they are |
It raises ValueError for a density at or below 0 (E334), a diameter
AERMOD would reject (E335), or convert and stokes that disagree.
The desktop GUI shows a source's Method 1 categories read-only; build
them in Python and load the project file. The diameter is checked as the source writer
will print it, to four significant digits, because that is the number
INPPDM reads: a mean-mass diameter of 0.00100006 microns is written as
0.001 and rejected, and 1000.04 is written as 1000 and accepted.
The source writer puts PARTDIAM and PARTDENS on the card to four
significant digits and MASSFRAX to six decimal places, so the deck
AERMOD reads rounds the diameters (a settling velocity changes by up to
about 0.1%; 0.07% for the AP-42 example above) and the written fractions
sum to 1 within 5e-7 per bin.
See the API reference for every function.