Skip to content

4. Tutorial 1 — Your First Point Source

Goal: Create a simple AERMOD input file (a deck) for a single smokestack emitting PM2.5, and understand what each setting means.

Time: 15--20 minutes

What you'll learn: - How to configure a project in the GUI - How to define a point source (smokestack) - How to set up a receptor grid - How to specify meteorology file paths - How to preview and download the generated AERMOD input file

Step 1: Set Up the Project

  1. Launch the GUI (pyaermod-app).
  2. On the Project step, fill in:
  3. Title (line 1): Tutorial 1 - My First Model
  4. Title (line 2): Single point source, PM2.5
  5. Pollutant: PM25
  6. Averaging periods: Select 24 and ANNUAL (a new project starts with 1 and ANNUAL; remove 1)
  7. Terrain: Flat (FLAT)
  8. Untick Regulatory default options (DFAULT). AERMOD ignores FLAT while DFAULT is on; the GUI shows a warning on the Project step if you leave it ticked.

What you just did: You told AERMOD what pollutant you're modeling (PM2.5), that the terrain is flat (no hills), and that you want annual and 24-hour average results.

The Project step: titles and pollutant, averaging periods and model options (EPA's Albany example; your values are the ones in the steps above)

Step 2: Add a Point Source

  1. Click Sources in the step list.
  2. Set Type to PointSource and click Add. An editor opens.
  3. Fill in the source form:
Parameter Value What It Means
Source ID STACK1 A short name for this source
X coord (m) 500000 Easting in UTM meters
Y coord (m) 3870000 Northing in UTM meters
Stack height (m) 50 The stack is 50 meters tall
Stack temp (K) 400 Exhaust gas temperature: 400 K (about 127 C)
Exit velocity (m/s) 15 Gas exits at 15 m/s
Stack diameter (m) 2 Stack opening is 2 meters across
Emission rate (g/s) 1.5 Emitting 1.5 grams of PM2.5 per second
Base elevation (m), under Advanced 0 Ground elevation at the stack base (meters)
  1. Click Save. (Close discards the source.)

What you just did: You defined a medium-sized industrial smokestack. The hot, fast-moving exhaust gas will rise well above the 50 m physical stack height (plume rise), so the "effective" release height might be 80--120 m depending on meteorological conditions. This is why AERMOD needs the temperature and velocity — not just the physical height.

You should see your source appear in the source table and as a marker in the plan view beside it.

The Sources step with one stack in the table and the plan view beside it (EPA's Albany example; your values are the ones in the steps above)

Step 3: Set Up Receptors

  1. Click Receptors in the step list.
  2. Set Type to CartesianGrid and click Add. In the editor, enter:
Parameter Value What It Means
Grid name GRID1 A short name for this grid
X init (m) 498000 Western edge of the grid
X num 21 21 points across: 4 km total width
X delta (m) 200 One receptor every 200 meters
Y init (m) 3868000 Southern edge
Y num 21 21 points up: 4 km total height
Y delta (m) 200 One receptor every 200 meters
  1. Click Save. The table shows the grid with the summary 21 x 21: 441 receptors.

What you just did: You placed a 4 km x 4 km grid of virtual air quality monitors centered on your source, with a receptor every 200 meters. AERMOD will calculate the ground-level PM2.5 concentration at each of these 441 points.

The Receptors step with a polar grid drawn on the plan view (EPA's Albany example; your values are the ones in the steps above)

Step 4: Specify Meteorology

  1. Click Meteorology in the step list.
  2. Under Met files, enter:
  3. Surface file: met_data.sfc
  4. Profile file: met_data.pfl

Note: You don't need actual meteorological files for this tutorial — we're just generating the input file. Because these files don't exist, the GUI marks the Meteorology step with an error and the header reads "Not ready to run". That is expected here. When you're ready to actually run AERMOD (Tutorial 3), you'll need real .sfc and .pfl files.

The Meteorology step: the surface and profile files, what the surface file holds, and the stations (EPA's Albany example; your values are the ones in the steps above)

Step 5: Preview the Input File

  1. Click Review & Run in the step list.
  2. Look at the Deck preview section. You'll see the complete AERMOD input file — a text file organized into five pathways:

  3. CO (Control): Project title, pollutant, options

  4. SO (Source): Your stack parameters
  5. RE (Receptor): Your grid definition
  6. ME (Meteorology): File paths
  7. OU (Output): What results to produce

  8. Click Download deck to save it. The download is named pyaermod_gui.inp; rename it aermod.inp.

What you just did: You generated a complete, valid AERMOD input file without editing a single line of text. Open the .inp file in a text editor and compare it to what the GUI showed you — they're identical.

Review & Run: the readiness checklist and the deck preview (EPA's Albany example; your values are the ones in the steps above)

Checkpoint

At this point you should understand:

  • [x] The five AERMOD pathways (CO, SO, RE, ME, OU)
  • [x] What stack height, temperature, velocity, and emission rate represent
  • [x] How a Cartesian receptor grid covers an area around the source
  • [x] That AERMOD needs hourly meteorological data in .sfc / .pfl format